the device and other parameters of the device–instrument; secondly, with errors related only to the method of measuring underlying the construction of this device. Because of this shared static error pas instrumental and methodological.

To include instrumental errors arising from friction in the bearings unnecessary gaps, inaccuracies manufacture, assembly and regulation units, changes in the elastic properties and linear dimensions of parts over time due to congestion and changes in temperature and so on.

To reduce the instrumental error in the devices used special materials injected joints, shielding, sealing and usually slander working limits of external conditions.

Methodical errors are caused by the principle of the device structure. They are not related to numerous factors give rise to instrumental error. Therefore, to reduce or eliminate their possible only by changing or replacement procedures and methods underlying parts of the measuring device.

Dynamic errors are caused inertial properties of the device. The presence of mechanical, thermal and other types of inertia leads to the fact that the readings are delayed by changing input values or reach new meaning after a long damped oscillations (sedation) or increasing (decreasing) in proportion to the rate of change of the input variable.

The oscillatory motion of moving parts of the appliance generates amplitude and phase errors due to moving the system to a new equilibrium. While oscillatory movement is not stopped or not the oscillation amplitude decreased to an acceptable limit, do not be counting.

Properties gear quickly suspend or reduce fluctuations in mobile parts to a certain value estimate time spent in comfort, which is calculated from the time of inclusion on the device for a half measurement range, until the mobile part it comes in relatively equilibrium state and fluctuations it does not exceed 1% of the entire range of the scale.